On Load Changeover Switches
- Range 63- 3150A in 6 frame sizes Conforming to IS 13947 part 3/93.
- Range 40-630A 1000V DC also available
- Available in 3P & 4P versions.
- Enhanced Insulation voltage
- High Mechanical & Electrical life.
- Mounting possible in both horizontal and vertical position.
- Available in Open Execution and Sheet Steel enclosures.
- Prewired Auxiliary contacts with 1NO 1NC.
- 2NO 2NC also available.
Load Break Switches
- Range 63- 3150A 4P with 100% Neutral Conforming to IS 13947 part 3/93.
- Arc Chute plates to quench arc within the switch and also enhance contact life.
- Compact body of fiber glass, reinforced polyester resin.
- Increased thermal withstand capacity of switch body.
- Bettered Insulation voltage.
- High Mechanical & Electrical life.
- Prewired Auxiliary contacts with 1NO 1NC
Automatic Transfer Switch
- The CME 360 Inbuilt Controller for all ratings from 40A to 1600A
- CME 360 – programmable & could override specific functions
- Unique feature of Fire & earthquake Protection System Linkage
- Current & Peak current – Measure & Display value Communicated on remote PC or Mobile App
- Cloud/ loT connected with Software – via Gateway
- Remote operation through PLC/ SCADA/ EMS & Password Protected
By Pass Switch
- Range 63-1600A 4P with 100% Neutral Conforming to IS 13947 part 3/93.
- Arc Chute plates to quench arc within the switch and also enhance contact life.
- Compact body of fiber glass, reinforced polyester resin.
- Increased thermal withstand capacity of switch body.
- Bettered Insulation voltage.
- High Mechanical & Electrical life.
- Mounting possible in both horizontal and vertical position.
- Prewired Auxiliary contacts with 1NO 1NC.
Switch Disconnector Fuses
- Range: 32A to 800A, TP,TPN & 4 Pole, 415V, 50Hz
- Conforms to latest IEC/IS specifications, IS/IEC 60947-3
- Tested at CPRI
- Multiple Roller Contact Mechanism for long life and better performance
- Available in open execution and sheet steel enclosure
Fuse Holders and Fuselinks
- Touch safe fuse holders are designed for all standard 22x58mm PV fuses
- High temperature resistance self extinguishing and halogen free thermoplastic material
- Optimised Ventilation
- 35 mm DIN Rail Mountable\
- Integral Fuse Puller design
Power Contactors 3P and 4P
- Conforms to IEC: 60947-4-1
- Reliable operation with compact and Robust construction
- Bounce free weld resistant contacts
- Very high mechanical and electrical endurance
- Frequency of operation: Maximum 600 operations per hour
- Standard Coil Voltages (AC): 24V, 42V, 48V, 110V, 220/240V, 380/415V
- Auxiliary contacts: 1NO+1NC or 2NO / 2NC
- Interchangeable with other ratings while upgrading electrical installations
- User-friendly Terminations.
Capacitor Duty Contactors
- Contactor Range: 9A-630A.
- Conforms to IEC: 60947-4-1
- Reliable operation with compact and Robust construction
- Bounce free weld resistant contacts
- Very high mechanical and electrical endurance
- Frequency of operation: Maximum 600 operations per hour
- Standard Coil Voltages (AC): 24V, 42V, 48V, 110V, 220/240V, 380/415V Auxiliary contacts: 1NO/1NC/1NO+1NC
- Capacitor duty contactor range 12KVAR – 50KVAR
Thermal Overload Relays
- Differential Bimetallic overload relays from 0.1 to 800A
- Built in 1NO+1NC potential free contacts
- Choice of Contactor or separate Mounting
- Option of Manual / Auto or Remote Reset
- Sealable cover to avoid tampering, Trip indicator
- Class 10A or Class 20
- Site Mounted add on accesories
Air Circuit Breakers
- Range 630A – 2000A
- Available in 3P & 4P Versions
- Icu 50kA, Icw 50kA for 1 sec. at 500Vac.
- Available in 3P & 4P Versions
- LSIG Protection with Microprocessor at variable time delay
- Digital display of current and voltage parameters
- Short circuit protection starts from 131%
Moulded Case Circuit Breakers
- Double Break Draw-Out MCCB
- Double Break Mechanism for Positive Isolation
- Higher Short-Circuit withstand capacity
- Appropriate Solution for Solar Installations
- Draw-Out without dismantling Cable/ Bus-Bar Terminations
MCB / RCCB / RCBO
- Double Break Draw-Out MCCB
- Double Break Mechanism for Positive Isolation
- Higher Short-Circuit withstand capacity
- Appropriate Solution for Solar Installations
- Draw-Out without dismantling Cable/ Bus-Bar Terminations
Digital Panel Meters
- Available in Class 1.0 & 0.5s
- Suitable for 3 Phase 4 Wire & 3 phase 3 Wire LT & HT Network
- Separate Active Energy (kWH) & Reactive Energy (kVARH) Pulse LED for onsite accuracy checking
- Test Mode Option to cross check connection & configured parameters
- Favorite display mode available to view required parameter only
- Voltage & Current THD available phase wise separately which indicate the quality of power received
Electronic Energy Meters
- Available in class 1 accuracy as per IS: 16444:2015 Part 1 & Class 0.5s as per IS16444:2015 Part 2.
- Meter rating available in Single Phase 5-30A/10-60A, 3Ph 10-60A/10-100A/20-100A, -/5A LTCT operated &-/5A HTCT operated variants.
- Internal latching relays for Demand & Load Control.
- Ideal for Remote Data Monitoring & Control, AMI/Smart grid.
- Tamper event detection, recording and reporting.
- Power event alarm such as Power Outage, Low & High voltage.
Wires and Cables
- Range : 0.5 to 400 Sq.mm in Single Core & Multicore.
- ZHFR insulation as per IS : 694.
- Multi strand 100% Pure annealed Electrolytic Grade Copper Conductor.
- Bunching of copper in uniform lay & diameter.
- Insulation PVC/XLPE/HR
- Armored/ Unarmored- GI Round wire/Flat Strip.
Lighting Products
- Made up of corrosion resistant unbreakable poly carbonate body
- High quality PC cover for LED linear lamp ensures soft and glare free lighting
- Specially designed aluminum housing for excellent Heat dissipation
- Ensures IP65 Protection
Fan
- Sweep 1200 mm
- Aerodynamically designed blades for high air delivery
- Separate chain cords for light & speed controls
- Low noise 3-Speed pull cord operation for speed regulations